Using Automatic mode
In automatic mode, the job computer regulates the degree of opening of the control valve and the main valve on the manifold such that the target rate defined for the application rate can be reached.
You are in automatic mode when one of the following icons appears in the spray data area of the work screen:
Preconditions
To use automatic mode, the following conditions must be fulfilled:
- ▪
- Rate has been entered.
- ▪
- Flow meter is calibrated.
- ▪
- A speed signal is available.
- ▪
- Working width is set.
- ▪
- The speed of the field sprayer is higher than the speed for the "Regulation off below" parameter.
- ▪
- The parameter "Regul. factor" has been set.
Mode of operation
In the following cases, the flow is automatically adjusted:
- ▪
- Speed of the field sprayer has changed.
- ▪
- Number of switched-on sections has changed.
- ▪
- You have changed the target rate manually.
- ▪
- The application rate has been changed by the information from the application map.
The speed and precision of the regulation depends on the value of the "Regul. factor" parameter.
You can change the target rate manually while driving in Automatic mode.
To operate this function the user needs the ME joystick first of all.
Procedure
To change the target rate during work:
- ⇨
- Spray cones appear under the boom icon on the work screen. Still, the sprayer is not spraying.
- 3.
- Exceed the speed defined in the "Regulation off below" parameter.
- ⇨
- The sprayer begins adjusting the application rate to the defined target rate.
- ⇨
- The degree of change appears on the work screen.