Using Automatic mode
In Automatic mode, Spraylight controls the spray pressure and the sections' main switch so the set value is reached.
You are in automatic mode when one of the following icons appears in the work screen:
Icon on the work screen
Meaning
Sprayer can apply.
The spray pressure will be regulated so that the set value is achieved.
The speed of the sprayer is below Auto.speed.
Sprayer can apply. Spray pressure is not regulated.
The speed of the sprayer is below Min. Speed.
Sprayer switches off automatically.
Mode of operation
 
The spray pressure will be adjusted automatically in the following cases:
Speed of the sprayer has changed.
The number of selected sections has changed.
You have changed the set value manually.
The speed and precision with which the set value will be adjusted depends on the value of the Reg.Value parameter.
You can change the set value manually while driving in Automatic mode.
 
 
Preconditions
 
 
Set value has been entered
Flow meter is calibrated
Wheel sensor is calibrated
Working width is set
The speed of the sprayer is higher than the set Auto.speed.
The Reg.Value parameter has been set.
 
 
Controls
 
 
Increase the set value by 10%
Reduce the set value by 10%
Set the set value to 100%