Calibrating non-ISO compliant nozzles
if you install a non-ISO compliant nozzle, or if you notice that your nozzles perform differently than that stipulated under ISO norms, you can re-calibrate the nozzles.
 
 
Procedure
 
 
1.
Switch to the Nozzle choice screen:
 Düsenauswahl 1
2.
Select the nozzle type. See Chapter Selecting the type of nozzle.
Select one of the nozzles from types A, B, C or D.
3.
 CAL - Press.
The following screen appears:
 
4.
Configure the nozzle. See the Table in these Operating Instructions.
Parameter
Meaning
Ref.Point1
Maximum output of the connected nozzle
at
Pressure when maximum output was measured
Ref.Point2
Minimum output of the nozzle
at
Pressure when minimum output was measured