Calibrating the hydraulics of the proportional valve
You must only calibrate the hydraulics of the proportional valve when you use a trailed implement with proportional valve.
Procedure
- þ
- TRAIL-Control is in manual mode.
- þ
- Ground is not sloped. Slope sensor must not recognize any slope. Otherwise the "Slope counter-steering" function will not work properly.
- þ
- You have enough space to drive straight ahead for about 30 seconds.
- 2.
- The "CALIBRATION" screen appears.
- 3.
- Set up the implement on flat ground in a line behind the tractor. Drive straight for a few meter until the tracks of the field sprayer run precisely into the tracks of the tractor.
or
– set the middle position with the function keys.
- 4.
- Stop the tractor as soon as the field sprayer is exactly in line behind the tractor.
- 5.
- Drive straight ahead very slowly. While driving, the friction of the wheel corresponds to the real working conditions and makes the calibration more precise. However, you can also perform this calibration while the implement is standing still.
- ⇨
- The following message appears:
"Hydr. output: Calibration is ready"
- ⇨
- The following message appears:
"Hydr. output: Calibration running"
- ⇨
- The trailed implement (or its drawbar or stub axle) now moves slowly to the left and then slowly to the right.
- ⇨
- This procedure may last up to 20 seconds.
- ⇨
- The calibration is completed when the message 'Hydraul. output: Calibration running." is no longer displayed.
- 8.
- Come to a stop.