Calibrating TRAIL-Control
 
WARNING
Danger of injury from trailed implement movement
When calibrating the proportional valve, the trailed implement moves automatically.
This may pose a risk to you and to persons in the immediate vicinity of the trailed implement.
1.
Ensure that nobody is in the regulation range of the trailed implement.
2.
Abort the calibration with the  TC_JR3_ASL_Prop Ventil Kalibrieren or  FS_JR3_DL prop Ventil function key as soon as someone approaches the trailed implement.
 
 
 
When should you calibrate?
 
 
 
Prior to initial start-up.
 
 
At the start of each season.
 
 
When inaccuracies occur.
 
 
 
Sequence
 
 
 
There are two steps involved in calibrating TRAIL-Control:
Step 1: Teach-in the middle position and end stops and calibrate the slope sensor.
 
In this step you teach the job computer the position of the drawbar and/or the axle in the middle, left and right positions.
 
The job computer calculates all intermediate positions itself.
 
To do so, the slope sensor must be installed. Its position may no longer be changed after this.
Step 2: Calibrating the hydraulics of the proportional valve
 
Only for trailed implements with proportional valves
 
In this step, the trailed implement is automatically steered to both sides and the voltages are measured.
 
The calibration runs automatically.
 
Further information
Teaching-in the central position and limit stops
Calibrating the hydraulics of the proportional valve