Calibrating the sensors for reproducing the boom slope
The purpose of the calibration process is to detect and save the boom position at maximum slope and in the horizontal position.
You must perform the calibration in the following instances:
- ▪
- Prior to initial start-up.
- ▪
- When the boom slope is not displayed correctly.
Illustration
The current boom position can appear at the following places:
- ▪
- Work screen
- ▪
- "BOOM SLOPE CONTROL" screen
The explanation for the display can be found in section: Reproducing the boom slope when turning
Procedure
To calibrate the angle sensor:
- 1.
- Position the field sprayer on level ground.
- ⇨
- The "BOOM SLOPE CONTROL" screen will appear.
- 4.
- Position the boom horizontally. The actual boom position is important here. The display on the screen is not calibrated yet at this time.
- ⇨
- You must now start the calibration within a few seconds.
- ⇨
- You have saved the horizontal position.
- 7.
- Slope the boom to the right.
- 9.
- Slope the boom to the left.