Company logo
Operating InstructionsSearchTable of contentsHome
 
 
Calculating correction values
In the final phase, you have determined:
Which parameters must be altered.
Whether the current delay must be increased or reduced.
You must now calculate the number of milliseconds by which to correct the incorrectly set parameter.
To do this, you will need to calculate a so-called correction value.
In order to be able to calculate the correction value, you need to find out how fast the sprayer was travelling. This speed must be entered in cm/milliseconds.
The following table lists a number of speeds and their conversion into cm/ms:
Speed in km/h
Speed in cm/ms
6 km/h
0.16 cm/ms
8 km/h
0.22 cm/ms
10 km/ h
0.28 cm/ms
 
 
Procedure
 
 
The correction value should be calculated as follows:
1.
[Distance P] : [Speed of sprayer] = Correction value
2.
This value must be entered for the “Delay correction on start” or “Delay correction on stop” parameter.